Feather Meal Anti-Corrosion Workshop

Feather Meal Anti-Corrosion Workshop

This 3,120 m² workshop in Changle, Weifang, Shandong produces 30,000 tons of feather meal annually under severe corrosive gases and humid steam. A customized multi-layer protection system was deployed: zinc-rich primer for cathodic protection, epoxy intermediate coat as a dense barrier, and polyurethane/fluorocarbon topcoat against UV and chemical attack, complemented by sealed envelope joints and dehumidification ventilation. With the coating remaining intact since operation, this project marks the establishment of Derun Heavy Steel's mature, replicable technical system for highly corrosive industrial environments.


Two-storey anti-corrosion steel workshop with dark gray profiled roof, white wall panels and continuous glazed windowsSide view of a steel workshop with gray wall cladding, exposed steel columns and exhaust fans installed outside

Project Overview

The Feather Meal Anti-Corrosion Workshop is a 3,120 m² steel structure building in Changle, Weifang, Shandong, China, designed for the production of 30,000 tons of feather meal annually. Its interior environment is among the most demanding in industrial construction: severe corrosive gases and humid steam are present throughout the production process.

Corrosive industrial environments attack unprotected steel rapidly – surface rust, coating breakdown and section loss can appear within months without a properly engineered protection system. The success of this project depended on a complete corrosion-protection strategy applied from design through fabrication and erection.

Derun Heavy Steel delivered the workshop as an integrated design-fabrication-installation package, with the anti-corrosion system specified and applied as part of the structural scope rather than left as an afterthought.

Client Requirements & Project Challenges

The client's core requirement was long-term structural integrity in a highly corrosive environment, combined with a production-friendly interior and normal project economy. Protecting steel against corrosive gases and humid steam requires more than paint – it requires a layered coating system matched to the environment and correctly applied.

The engineering challenge lay in selecting and executing a protection system that would survive the combination of chemical attack and humidity, while also ensuring that envelope joints remained sealed and the interior stayed ventilated to reduce moisture accumulation.

Derun's Engineering Solution

Derun Heavy Steel deployed a customized multi-layer protection system built on four lines of defence. A zinc-rich primer provides cathodic protection – even where the coating is scratched, the zinc layer protects the steel substrate. An epoxy intermediate coat forms a dense barrier against moisture and aggressive gases. A polyurethane or fluorocarbon topcoat provides resistance to UV and chemical attack. Sealed envelope joints and dehumidification ventilation complete the system by reducing the moisture load inside the building.

Each layer was applied to controlled thickness and quality-checked before the next, following the coating specification for the environment. Structural members were selected and detailed so that sharp edges, crevices and inaccessible pockets – the weak points of any coating system – were minimised.

All primary members use Q235B/Q355B steel with international equivalents available on request, fabricated in our own factory with monthly capacity above 2,000 tons.

Key Project Data

ItemDetails
Project NameFeather Meal Anti-Corrosion Workshop
LocationChangle, Weifang, Shandong, China
Floor Area3,120 m²
Production Capacity30,000 tons feather meal per year
EnvironmentSevere corrosive gases, humid steam
Protection SystemZinc-rich primer + epoxy intermediate + polyurethane/fluorocarbon topcoat
Additional MeasuresSealed envelope joints, dehumidification ventilation
Main MaterialQ235B/Q355B steel (ASTM/EN equivalents available)
Structure TypeSteel portal frame workshop
WarrantySpecified in the project contract

Quality Control & Delivery

Quality control on a corrosion-protection project centres on the coating process itself. Surface preparation, layer thickness and curing conditions were monitored during fabrication so that the protection system left the factory as specified. On site, erection sequences were planned to avoid damaging completed coatings, with touch-up procedures applied where required.

Since the workshop entered operation, the coating has remained intact – evidence that the specified system and its controlled application are performing as designed in the corrosive environment.

Project Outcome

This project marks the establishment of Derun Heavy Steel's mature, replicable technical system for highly corrosive industrial environments. The approach – environment analysis, layered protection specification, controlled application and sealed detailing – can be applied to similar facilities such as chemical plants, rendering facilities, tanneries and salt-processing buildings.

For clients, the outcome is a production building with predictable long-term maintenance costs, because the structure was protected against the environment from day one rather than repaired after damage appears.

Project Execution Notes

Feather meal processing is one of the more demanding environments for a steel building. Hydrolysis, drying and the residues left behind are both corrosive and hygroscopic, and a standard pre-engineered building will show its age quickly in that setting. For this workshop, the anti-corrosion specification was set with those conditions in mind, including the coating system on primary members, the finish on exposed girts and purlins, and the choice of fasteners and sealing details at roof and wall joints.

We also paid attention to drainage and condensation control. Warm, moist air inside a processing workshop meets a cooler roof surface, and without appropriate insulation, ventilation and drainage design, internal condensation will shorten the life of both the steel and the wall linings. The roof and wall details were specified to manage that moisture rather than assume it away.

For clients running rendering, drying or organic waste processing lines, our recommendation is to treat the building envelope as part of the production equipment, not as a shelter over it. The incremental cost of a more robust coating and ventilation system is small compared with the maintenance downtime that comes when a standard building is placed in a corrosive environment it was not specified for.

Frequently Asked Questions

1. Can Derun design corrosion protection for our specific environment?

Yes. We analyse the corrosive agents, humidity and operating conditions, then specify an appropriate layered protection system.

2. How long does the coating last in corrosive environments?

Coating life depends on environment severity, layer specification and maintenance. Our system is engineered for long service in the intended conditions; details are customized per project.

3. Can the workshop be cleaned or washed internally?

Yes. The sealed envelope and drainage detailing are designed for the washdown and cleaning routines typical of processing facilities.

4. What steel grades are used?

Q235B/Q355B steel is standard, with international equivalents such as ASTM A36/A572 and EN S275/S355 available on request.

5. Is ventilation included in the scope?

Ventilation design is coordinated with the structural scope to control humidity; specific systems are customized per project.

6. Can you build similar anti-corrosion facilities?

Yes. The same technical system applies to chemical plants, rendering facilities and other corrosive processing environments.

Related Steel Structure Solutions

Start Your Steel Structure Project

1. Send Your Requirements – describe your production environment and building needs through the contact form or email; our engineers confirm the key parameters with you.

2. Review Design & Quotation – we prepare the structural design, protection specification and itemized quotation; you review, adjust and confirm the order.

3. Fabrication & Delivery – production starts after confirmation; your workshop is fabricated, coated, inspected, packed and delivered on schedule.

Get a Quote

Building for a corrosive or demanding industrial environment? Send your requirements to our engineers, and you will receive a response as soon as your requirements are confirmed.

Get In Touch With Us